Perform insulation and resistance test on page 6.
Floor sensor resistance.
Test the floor temperature sensors using a multimeter to verify accuracy of the sensors.
Every comfortzone electric underfloor heating thermostat should be set up with a floor temperature sensor probe to monitor the temperature of your floor.
Replacement floor temperature sensor suitable for a wide range of underfloor heating thermostats.
Warmup heating cables are constant wattage cables that should be tested on a 200 ohm scale.
10k ntc th232 resistance sensor circuit resistance.
Test 4 temperature sensor.
Describes the situation the problem occurs or the environment that the question applies to including products affected.
Every comfortzone electric underfloor heating thermostat should be set up with a floor temperature sensor probe to monitor the temperature of your floor.
Always ensure resistance matches the information on the product tag.
Set the multimeter for resistance at 10k ω 2 at room temperature and take a reading between the sensor leads.
To answer your question the resistance reading will be different on different floor probes the sensor and stat resistance readings must match in order for the system to operate correctly.
If a different sensor is used it would give false readings to the thermostat and potentially cause the system to not work.
The slab sensor 079 is commonly used for floor temperature sensing in floor heating applications.
Ensure the probe s tip is located in an area that can represent the overall floor temperature and away from other heating cooling sources.
Works with a wide range of different thermostatsplease check the resistance values of your current sensor against the table below for compatibility 3 metre long cable cable has high rigidity allowing it to be easily passed through existing flexible conduit suitable for use in wet areas.
Suitable for use in wet areas ip68.
The thin casing allows for retrofit installation between tile spaces if necessary.
What is the resistance of the floor sensor circuit for the aube th232 underfloor heating thermostat.
The resistance will vary according to the temperature i e the colder the sensor the higher the resistance.
3 meter floor temperature sensor probe for underfloor heating thermostat features works with a wide range of different thermostats.
This video shows you how to test the resistance of your sensor probe correctly to identify any faults.
Duct tape the floor sensor probe on top of the nuheat mat.
Please check the resistance values of your current sensor against the table cable has high rigidity allowing it to be easily passed through existing flexible conduit.
Secure floor sensor probe.
To ensure that your floor heating system will function properly always test the resistance of your wires with a digital multimeter set to 200 ohms before during and after installation.